10 Technical Specifications
Note: Only recommended for use on Bell POTS lines or dial tone provided by ToolVox
®
; locations with
private PBX head end phone systems should explore the rest of Code Blue’s speakerphone options.
Telephone & elecTronic inTerface
Ringer Equivalence Num-
ber
FCC REN AC = 0.1 DC = 0.25
Surge Suppressors Telephone interface FCC part 68
Approved
Signaling DTMF (tone)
Loop Current 27-50 mA
Auxiliary Output Dry contact relay 120mA maxi-
mum. Normally open relay. Form
C.
System Connections Individual phone lines or PBX
extensions recommended
environmenTal
Operating Tempera-
ture Range
-22
0
to 150
0
F
Operating Relative
Humidity
0% to 95% RH
Non-condensing
Electrostatic Dis-
charge
20kV
Faceplate Stainless steel, piezoelectric
weatherproof button, microphone and
speaker openings reduce damage
from vandalism, waterproof 3½"
speaker, waterproof microphone
physical
Dimensions (face-
plate)
IA 500 7" w x 7" h x 2" d
16 Gauge Stainless Steel
IA 501 9" w x 9" h x 3½" d
12 Gauge Stainless Steel
Faceplate
14 Gauge Painted Steel
Backbox
8¼" w x 8¼" h
Remote Mount
Electronics
Speakerphone electronics are
conformal coated to withstand harsh
environmental conditions.
InterAct 500-s
Single Button
Surface Mount
InterAct 500-d
Dual Button
Surface Mount
InterAct 501-d
Dual Button
Flush Mount
InterAct 501-s
Single Button
Flush Mount